The friction head loss is calculated using the Darcy-Weisbach equation:
| Input | Value | Unit | | --- | --- | --- | | Flow rate (Q) | | m^3/s | | Length of pipe (L) | | m | | Diameter of pipe (D) | | m | | Elevation of suction point (Zs) | | m | | Elevation of discharge point (Zd) | | m | | Friction factor (f) | | - | | Velocity of fluid (V) | | m/s | booster pump head calculation xls
Hf = 0.02 * (1000/0.1) * (1.5^2/2*9.81) = 2.29 m Hs = 20 - 10 = 10 m Hm = 10% of H = 0.1 * (2.29 + 10) = 1.23 m H = 2.29 + 10 + 1.23 = 13.52 m The friction head loss is calculated using the
Please note that this is a simplified example and actual calculations may require more complex formulas and considerations. booster pump head calculation xls